USE
- GENIUS is a level monitor in atmospheric tanks.
- The level measurement is made measuring the static pressure of the liquid height through a tube into the tank.
- It allows to measure the level in rectangular and cylindrical, horizontal or vertical, tanks with a maximum height of 4 m.
- Level reading in height (mm or inches) or volume (litres or gallons)
- It is suitable for liquids with a maximum viscosity of 30 cSt.
* It is not suitable for ATEX classified zone installation.
COMPOSED OF
- Probe with 10 metres of tube (extending at 50 m maximum) of 6 mm and with a weight in the other end that is immersed in the liquid till touching the bottom.
- Control unit to see the liquid level and configuration
- Two outlets to connect two alarm or control devices
- PC communication connection via RS485 port
- Acoustic alarm in its inner of 90 dB and 2400 Hz
TECHNICAL FEATURES:
- Power: 230 VAC · 110 VAC · 15-32 VDC
- IP-55 Protection
- Accuracy: ±1 % in height
- Resolution: 5 mm
Configuration of:
- Tank type and dimensions, calibration
- Level alarms
- Level reading type
- Measuring unit
- According to the programmed alarm levels, the control unit will activate or deactivate the contacts, acting as a remote switch for the alarm device operation or the connected control kit operation.
- PC communication kit through the RS-485 communication port
- Connection to PC or GK-7 controller or similar